The COI LINC tape hoard responds to all IOTs in the 676X and 677X range: 6760 Output, no clear 6761 C1 Input, OR 6762 Output, no clear 6763 C1 Input, OR 6764 C0 Output, clear 6765 C0 Output, clear 6766 C0 Output, clear 6767 C0 Output, clear 6770 Output, no clear 6771 Output, no clear 6772 C1 Input, OR 6773 C1 Input, OR 6774 C0 Output, clear 6775 C0 Output, clear 6776 C0 Output, clear 6777 C0 Output, clear C0 is asserted (low) for all IOTs with bit 9 set, provided XDONE is set. C1 is asserted (low) for IOTs which are in 676[13] or in 677[23], again provided XDONE is set. (The operation of the IOTs appears to be undefined if the device is busy.) thes IOTs also present data on the DATA bus. The device handles book-keeping for 3-cycle DMA, performing transfers as requested by the device until XDONE, which will inhibit further DMA. (It is up to the device to set XDONE when notified of OVERFLOW.) TC08 Instructions: 6761 DRTA Input, OR -- Read Status register A 6762 DTCA Clear Status register A 6764 DTXA 6771 DTSF 6772 DTRB 6774 DTLB and their microcoded combinations, as allowed by Posibus. It would appear that to the extent that can be determined, this device is (or could be) compatible with the TC08.