1 /MI8-EC (TC08 DECtape) 2 DTLA=6766 / LOAD REGISTER A 3 DTSF=6771 / SKIP ON FLAGS 4 DTLB=6774 / LOAD REGISTER B 5 FIELD 0 6 *7554 7 007554 7600 START, 7600 / CLA; ALSO LOADING ADDRESS, AND COUNT 8 007555 6774 DTLB / TRANSFER TO FIELD 0 9 007556 1374 TAD MOVE / GET A MOVE COMMAND 10 007557 6766 DTLA / MOVE 11 007560 6771 DTSF / WAIT FOR IT 12 007561 5360 JMP .-1 13 007562 7240 CLA CMA / GET LOADING ADDRESS - 1 14 007563 1354 TAD START 15 007564 3773 DCA I IDCA / SET CA 16 007565 1354 TAD START / GET COUNT 17 007566 3772 DCA I IDWC / SET WC 18 007567 1375 TAD READ / GET A READ COMMAND 19 007570 6766 DTLA / READ 20 007571 5376 JMP WAIT / GO WAIT 21 007572 7754 IDWC, 7754 / PTR TO WC 22 007573 7755 IDCA, 7755 / PTR TO CA 23 007574 0600 MOVE, 0600 / MOVE, NORMAL, GO 24 007575 0220 READ, 0220 / READ, GO 25 007576 6771 WAIT, DTSF / WAIT FOR THE READ 26 007577 5376 JMP .-1 27 / WHEN THE READ IS FINISHED, FALL THROUGH ONTO THE NEWLY LOADED CODE. 28 *7600 29 007600 7777 7777 / REPLACED BY THE LOADED CODE. 30 007601 7777 7777 / (ALL DIODES REMOVED) 31 007602 7777 7777 32 007603 7777 7777 33 007604 7777 7777 34 007605 7777 7777 35 007606 7777 7777 36 007607 7777 7777 37 007610 7777 7777 38 007611 7777 7777 39 007612 7777 7777 40 007613 7777 7777 41 $