/50 / / /%R COLLECT INSPECTOR DEFECT AND SPLICE DATA / /%TW COME HERE FROM "MEMORY" FOR EACH MOTION / PULSE AND MOVE THE INSPECTOR DEFECT DATA TO CHANNEL / STORAGE. / /%TD WHEN THE LASER SHUTTERS ARE CLOSED, AND THE EXERCISER / IS OFF, DEFECT DATA IS SET IN MEMORY FOR ALL THREE / INSPECTION CHANNELS. IF THE INSPECTOR IS ACTIVE, OR / THE EXERCISER IS ON, THE DEFECT LINES ARE MONITORED / AND DEFECT DATA IS SAVED FOR LATER ENTRY INTO THE / DEFECT MEMORY TABLE (SEE DEFCH1,2,3). THE SPLICE / SIGNAL FROM CHANNEL 2 IS ALSO MONITORED AND THAT / DATA IS SAVED FOR "DEFCH2". / / DEFDAT, 0 DBRI50 /READ THE DEFECT AND SPLICE BITS AND (0017) DBCI50 /CLEAR THE DEFECT BITS FROM THE INPUT MQL TAD SHUTDY /IS THE SHUTTER OPENING DELAY ACTIVE ? SNA CLA JMP .+3 /NO, GO ON TAD (7) /YES, FORCE ALL DEFECT BITS SET, BUT MQL /NOT THE SPLICE BIT ACL /ARE ANY BITS SET ? SNA JMP I DEFDAT /NO, RETURN AND P4 /YES, PROCESS CHANNEL 1 DATA SZA DCA DEFCT1 ACL /PROCESS CHANNEL 3 DATA AND P1 SZA DCA DEFCT3 TAD DEFCT2 /"OR" THE NEW DATA WITH THE PREVIOUS MQA /DATA FOR CHANNEL 2 AND (0012) DCA DEFCT2 JMP I DEFDAT /RETURN