Author: Roger A. Nace, University of Washington,
Anesthesia Research Center, Seattle, Washington
HISTO12 is an interspike interval plotting routine. The program
uses an adiustable threshold to discriminate against baseline
noise and will eliminate spikes shorter than 500 us or
longer than 2.1 ms. A limit to the number of spikes counted
may be selected. Printed output consists of sampling diagnostics,
total spikes counted, the average input frequency, total
time in sampling, and number of spikes not appearing in the
display. The display in either scattergram or histogram mode
may be expanded horizontally defining intervals of 0.0 to 0.2
to 0.0 to 1.6 seconds. Vertical scaling is accomplished by
addition, subtraction or by multiplication, division. Complete
operating instructions type out upon program startup.
Source Language: LAP6-DIAL
Catalog: July 1974