HIST PLOT: A Versatile Program for Cross Correlation of Point Process Data on a PDP-12
| 12-169
|
Author: Stephen C. Woods, John T. Williams, Eric Halgren,
Thomas L. Babb, UCLA Center for Health Sciences,
Los Angeles, California
HSTPLT is a multi-option program for cross-correlating two STAP-12
compatible event trains. When one train is designated as a reference
train, various long or short pre- and post-reference times may be
selected and all or only certain reference events may be selected
for computation. The computed histogram with calibrations for time
and numbers of events may be plotted and simultaneously individual
bin counts may be printed.
Minimum Hardware: PS/8, OS/8 or OS/12 Operating System,
LINCtape or other mass storage device, EAE
Other Programs Needed: QANDA modified
Storage Requirement: 8K
Restrictions: Not restartable
Source Language: PAL-12 or PAL-8
Catalog: December 1974