A Set of Spectral ngrams
| 12-99
|
Author: Cyril H. Nute,
Naval Medical Neuropsychiatric Research Unit,
San Diego, California
XSPECT is a pair of programs written for the PDP-12 computer.
Program XS, written in DIAL, accepts 2048 digital data
measurements for each of two EEG channels, written on one
reel of LINCtape mounted on Unit 0. This input record may be
created from analog voltages input to the AD12 analog-to-digital
converter, using the two D.E.C. programs, ADTAPE
and ADCON. The output of programs XS is a three-black
record written on the "intermediate output tape", mounted on
Unit 1.
The second program of the set is $XS, written in FOCAL-12,
under the DIAL-MS monitor system. It accepts a three-block
intermediate record from the LINCtape mounted on Unit 1, and
uses the ASR33 teletype to create a listing of two auto-power density
spectra, plus the coherence and phase relationships between the
two EEG data channels. Frequencies are written on the left
edge of the paper, with each line of output representing a
.5-Hz frequency interval.
Minimum Hardware: 8K PDP-12, AD12 analog-to-digital
converter, KW12 Clock,
2 LINCtape units, ASR33
Other Programs Needed: DIAL-MS Monitor System, with
FOCAL-12; QANDA; FFT
(DECUS NO. 8-143)
Restrictions: Need two channels of input data
on LINCtape, sampled at 128 Hz
for 16 sec; output resolution in
.5 Hz. May be changed by contacting
the author
Source Language: DIAL
Catalog: July 1974