HEADING:H951 MINI-PROBE CAP TRIMS (P20043.C4) S&R 25'S 4/13/98 GF


STEP
  1   GOTO  STEP 9
  2   GOTO  STEP 197
  3   GOTO  STEP 172
  4   PRIN  STRG 40 STRG 3
  5   QUIT
  6   GOTO  STEP 252
  7   GOTO  STEP 263
  8   IF  DUM 807 = 00 THEN   LET  DUM 807 = 01
  9   IF  DUM 801 = 00 THEN   GOTO  STEP 263
 10   GOTO  STEP 13
 11   GOTO  STEP 219
 12   GOTO  STEP 120
 13   MOVE   POS 990  SPD 0
 14   IF  DUM 807 = 00 THEN   GOSU  STEP 139
 15   GOSU  STEP 229
 16   LET  DLTA 900 = POS 900 - POS 899
 17   DISP   DLTA 900
 18   MOVE   POS 899  SPD 0
 19   TEST   UNK 55  CODE 56  TOL 55  ACC 22  REJ 0  REG 0
 20   PRIN  "BAD CONTACT ON PROBE CARD, CHECK SCAN'S A0,B0" STRG 3
 21   QUIT
 22   LET  I = 00
 23   LET  L = 00
 24   GOSU  STEP 85
 25   IF  DUM 1 > 03 THEN   IF  DUM 1 < 2.70000E+01 THEN   GOTO  STEP 39
 26   LET  L = L + 01
 27   IF  L = 03 THEN   GOTO  STEP 31
 28   SMOV   DLTA 666  SPD 0  REG 0
 29   SMOV   DLTA 667  SPD 0  REG 0
 30   GOTO  STEP 24
 31   PRIN  STRG 3 ">    >   >  BAD PROBE CONTACT   <   <    <"
 32   PRIN  STRG 3 "> ADJUST PROBES , HIT RETURN TO TEST CAP <"
 33   PRIN  STRG 3 "> WHEN PROBES ARE OK TYPE '1' TO CONTINUE <"
 34   PRIN  STRG 3 "ENTER COMMAND # > " STRG 1
 35   READ  TTY:;DUM 55 %1.0 THEN   QUIT
 36   GOSU  STEP 85
 37   GOSU  STEP 107
 38   IF  DUM 55 # 01 THEN   GOTO  STEP 34
 39   LET  DUM 100 = DUM 1 - NOM 1
 40   IF  DUM 100 < TOL 1 THEN   LET  REG 1 = 01
 41   IF  DUM 100 > ! TOL 1 THEN   LET  REG 1 = 01
 42   IF  REG 1 = 00 THEN   GOTO  STEP 44
 43   PRIN  "*** PRE-TRIM REJECT ***" STRG 3
 44   GOSU  STEP 113 1.00000E+03
 45   IF  REG 1 # 00 THEN   GOTO  STEP 75
 46   LET  DUM 809 = 00
 47   FOR  I = 1.00000E+00 TO 9.00000E+00 
 48   IF  I = 9.00000E+00 THEN   IF  DUM 809 < 8.00000E+00 THEN   GOTO  STEP 69
 49   LET  J = I + 1.00000E+02
 50   LET  DUM 55 = DUM 1 - DUM J
 51   IF  DUM 55 < NOM 1 THEN   GOTO  STEP 69
 52   LET  DUM 55 = DUM 1
 53   LET  L = I * 02
 54   LET  K = L - 01
 55   MOVE   POS K  SPD 0
 56   SERP   UNK 55  CODE 55  CUT 55  MODE 55  POS L  DENS 1  BRAN 0
 57   MOVE   POS L  SPD 0
 58   SERP   UNK 55  CODE 55  CUT 55  MODE 55  POS K  DENS 1  BRAN 0
 59   LET  DUM 809 = DUM 809 + 01
 60   GOSU  STEP 85
 61   LET  J = I + 5.00000E+02
 62   LET  K = I + 6.00000E+02
 63   LET  L = I + 9.00000E+02
 64   LET  DUM 55 = DUM 55 - DUM 1
 65   IF  DUM 55 < 6.00000E-02 THEN   GOTO  STEP 69
 66   LET  DUM J = DUM J + DUM 55
 67   IF  DUM 55 > DUM K THEN   LET  DUM K = DUM 55
 68   LET  DUM L = DUM L + 01
 69   NEXT  I
 70   LET  DUM 100 = DUM 1 - NOM 1
 71   IF  DUM 100 < TOL 101 THEN   LET  REG 2 = 01
 72   IF  DUM 100 > ! TOL 101 THEN   LET  REG 2 = 01
 73   IF  REG 2 = 00 THEN   GOTO  STEP 78
 74   PRIN  "> TRIM REJECT <" STRG 3
 75   PRIN  "C= " DUM 1 " PF,  " DUM 100 " PF DEV FROM NOM" STRG 3
 76   MOVE   POS 99  SPD 0
 77   REM  "NIBL DLTA 99 POS 100 DENS 3 BRAN 0"
 78   IF  DUM 807 # 4.90000E+01 THEN   GOTO  STEP 82
 79   LET  STRG 1000 = STRG 300 + " " + STRG 333
 80   MOVE   POS 101  SPD 0
 81   CGEN  DENS 2 SCAL 1 POS 102 STRG 1000
 82   MOVE   POS 899  SPD 0
 83   LET  REG 1 = 00
 84   EXIT
 85   LET  K = 00
 86   FOR  J = 1.00000E+00 TO 1.00000E+01 
 87   LET  DUM J = 00
 88   NEXT  J
 89   LET  K = K + 01
 90   TALK  DEV 10 STRG 10
 91   FOR  J = 1.00000E+00 TO 5.00000E+02 
 92   NEXT  J
 93   LISN  DEV 2 WAIT 1 "_" 01 STRG 11 0.00000E+00 02 STRG 12 
      NOM 3 01 STRG 13 NOM 2 %1.0 THEN   GOTO  STEP 111
 94   FOR  J = 1.00000E+00 TO 2.00000E+02 
 95   NEXT  J
 96   LET  DUM K = NOM 3 * 1.00000E+06
 97   IF  K < 2.00000E+00 THEN   GOTO  STEP 89
 98   LET  DUM 888 = DUM 888 + 01
 99   LET  J = K - 01
100   LET  DUM 804 = DUM J - DUM K
101   PRIN  " " DUM 804
102   IF  DUM 804 > TOL 88 THEN   IF  DUM 804 < ! TOL 88 THEN   GOTO  STEP 105
103   IF  K = 1.00000E+01 THEN   GOTO  STEP 109
104   GOTO  STEP 89
105   LET  DUM 1 = DUM K
106   IF  BIT 10 # 00 THEN   GOTO  STEP 108
107   PRIN  "C=" DUM 1 " PF  FNGR# " I
108   EXIT
109   PRIN  STRG 3 "> ERROR! CAP VALUES NOT STABLE! CALL ENG! <"
110   QUIT
111   PRIN  STRG 3 "ERROR, CANNOT TALK TO CAP METER!" STRG 3
112   EXIT
113   IF  DUM 1 < 02 THEN   IF  DUM 1 > DUM 110 THEN   GOTO  STEP 117
114   LET  DUM 500 = DUM 500 + DUM 1
115   LET  DUM 600 = DUM 600 + ( DUM 1 * DUM 1 )
116   LET  DUM 700 = DUM 700 + 01
117   LET  J = DUM 807 + VALU 1
118   LET  DUM J = DUM 100
119   EXIT
120   GOSU  STEP 165
121   PRIN  " PART    INIT DEV  TRIM DEV"
122   LET  DUM 804 = 00
123   FOR  I = 1.00000E+00 TO 4.90000E+01 
124   LET  J = I + 1.00000E+03
125   LET  K = I + 1.10000E+03
126   PRIN  " " STRG 1
127   IF  I < 1.00000E+01 THEN   PRIN  " " STRG 1
128   PRIN  I "   " %5.2 DUM J "  " %5.2 DUM K STRG 1
129   IF  DUM K > ! TOL 101 THEN   PRIN  "<<< REJ-HI" STRG 1
130   IF  DUM K < TOL 101 THEN   PRIN  "<<< REJ-LOW" STRG 1
131   IF  DUM K > ! TOL 101 THEN   GOTO  STEP 134
132   IF  DUM K < TOL 101 THEN   GOTO  STEP 134
133   LET  DUM 804 = DUM 804 + 1.00000E+00
134   PRIN  " "
135   NEXT  I
136   PRIN  " "
137   PRIN  DUM 804 " GOOD PARTS"
138   QUIT
139   FOR  I = 1.00100E+03 TO 1.05000E+03 
140   LET  J = I + 1.00000E+02
141   LET  DUM I = 9.99900E+03
142   LET  DUM J = 9.99900E+03
143   NEXT  I
144   EXIT
145   FOR  J = 1.00000E+00 TO 1.90000E+01 
146   IF  DUM 333 = MASK J THEN   GOTO  STEP 152
147   NEXT  J
148   PRIN  STRG 3
149   PRIN  "THAT PART NUMBER IS NOT AVAILABLE , TRY AGAIN. . ." STRG 3
150   PRIN  STRG 3
151   GOTO  STEP 219
152   LET  I = DUM 333
153   LET  L = 1.00000E+02 + ( REG I * 1.00000E+01 )
154   FOR  J = 1.01000E+02 TO 1.10000E+02 
155   LET  K = J + L
156   LET  DUM J = DUM K
157   NEXT  J
158   LET  DUM 334 = I
159   LET  NOM 1 = NOM I
160   LET  TOL 101 = TOL I
161   LET  TOL 153 = TOL 151 * TOL 101
162   LET  TOL 154 = TOL 152 * DUM 110
163   LET  TOL 1 = TOL 153 + TOL 154
164   LET  STRG 300 = STRG I
165   PRIN  "NOW TRIMMING PART # > 307-" STRG 300
166   PRIN  STRG 3
167   PRIN  "CURRENT LOT # IS > " STRG 333
168   PRIN  " "
169   PRIN  "NOMINAL = " NOM 1 " PF"
170   PRIN  " "
171   EXIT
172   PRIN  STRG 3
173   PRIN  "PART: 307-" STRG 300 "    LOT: " STRG 333
174   PRIN  ""
175   PRIN  "PRINT VALUE DATA FOR " DUM 700 " PARTS"
176   PRIN  ""
177   PRIN  "# OF 'EXTRA' CAP METER TESTS = " DUM 888
178   PRIN  " "
179   LET  DUM 55 = DUM 500 / DUM 700
180   LET  DUM 800 = ( DUM 600 - ( DUM 500 * DUM 500 / DUM 700 ) )
181   LET  DUM 800 = SQRT ( DUM 800 * DUM 800 )
182   LET  DUM 800 = SQRT ( DUM 800 / ( DUM 700 - 01 ) )
183   PRIN  "      AVERAGE(PF)  STD DEV(PF)"
184   PRIN  "C1" %9.3 DUM 55 %11.4 DUM 800
185   PRIN  ""
186   PRIN  "           AVERAGE     HIGHEST     # OF BARS"
187   PRIN  "         CHANGE (PF)  CHANGE (PF)    TRIMMED"
188   PRIN  ""
189   FOR  I = 5.01000E+02 TO 5.09000E+02 
190   LET  J = I + 1.00000E+02
191   LET  K = I + 4.00000E+02
192   LET  DUM 55 = DUM I / DUM K
193   PRIN  STRG I %9.2 DUM 55 STRG 1
194   PRIN  %10.2 DUM J %10.0 DUM K
195   NEXT  I
196   QUIT
197   PRIN  STRG 5
198   GOSU  STEP 139
199   LET  DUM 1 = 00
200   LET  DUM 55 = 00
201   LET  DUM 700 = 00
202   LET  DUM 888 = 00
203   FOR  I = 8.00000E+02 TO 8.08000E+02 
204   LET  DUM I = 00
205   NEXT  I
206   LET  DUM 801 = 1.00000E+00
207   FOR  I = 5.00000E+02 TO 5.09000E+02 
208   LET  DUM I = 00
209   LET  J = I + 1.00000E+02
210   LET  DUM J = 00
211   LET  J = I + 4.00000E+02
212   LET  DUM J = 00
213   NEXT  I
214   LET  NOM 2 = 00
215   LET  NOM 3 = 00
216   GOSU  STEP 145
217   PRIN  "DUMMIES ZEROED" STRG 3
218   QUIT
219   GOSU  STEP 165
220   PRIN  "ENTER NEW PART # > " STRG 1
221   READ  TTY:;DUM 333 %1.0 THEN   QUIT
222   PRIN  "ENTER NEW LOT # > " STRG 1
223   READ  TTY:;"_" STRG 334 %1.0 THEN   QUIT
224   LET  J = 01
225   LET  K = 04
226   LET  STRG 333 = J K STRG 334
227   LET  DUM 801 = 01
228   GOTO  STEP 2
229   IF  DUM 807 = 00 THEN   GOTO  STEP 236
230   PRIN  STRG 3
231   PRIN  "PART # >" DUM 807 "< WAS TRIMMED LAST."
232   PRIN  STRG 3
233   PRIN  "WHICH PART DO YOU WANT TO START ON ? " STRG 1
234   READ  TTY:;DUM 808 %1.0 THEN   QUIT
235   LET  DUM 807 = 00
236   SHOM   REG 30
237   SHOM   REG 0
238   ALIN   POS 998  REF 999  REG 998
239   ALIN   POS 0  REF 0  REG 0
240   LET  I = 00
241   GOSU  STEP 85
242   IF  DUM 1 > - 3.00000E-02 THEN   IF  DUM 1 < 3.00000E-02 THEN   GOTO  STEP 245
243   PRIN  "CAP METER NOT ZEROED, MUST SET BEFORE TRIMMING" STRG 3
244   QUIT
245   LET  DLTA 998 = POS 997 - POS 999
246   GOSU  STEP 256
247   LET  DLTA 998 = DLTA 998 + DLTA 999
248   GOSU  STEP 256
249   IF  DUM 807 < DUM 999 THEN   GOTO  STEP 247
250   LET  DUM 807 = 00
251   LET  DUM 808 = 00
252   SHOM   REG 30
253   SHOM   REG 31
254   SHOM   REG 32
255   QUIT
256   LET  DUM 807 = DUM 807 + 01
257   IF  DUM 808 > DUM 807 THEN   EXIT
258   SMOV   DLTA 998  SPD 0  REG 0
259   LET  DLTA 998 = 00
260   PRIN  "PART # " DUM 807
261   GOSU  STEP 16
262   EXIT
263   PRIN  "SETUP FOR PART NUMBER > " STRG 300 " <, TYPE 11^T TO CHANGE."
264   PRIN  "LOT NUMBER IS " STRG 333
265   QUIT
MODE
 55   TURN 55  CROS 0  INC 55
DENS
  1   SPD 1  PWR 1
  2   SPD 2  PWR 1
  3   SPD 3  PWR 1
UNK
 55   NOM 55  SCAN 55  MAT 0  FUNC 0  DUM 55
DEV
  2   0101
 10   041
REG
  1   00
  2   00
  3   00
  4   00
 30   03
 31   00
 32   04
333   00
397   00
472   03
806   00
837   01
838   00
846   01
861   01
936   02
991   04
998   -01
999   0774
1158   03
1225   00
1226   00
1272   00
1326   05
1327   00
1328   00
1329   01
1352   03
MASK
  1   01446
  2   01505
  3   01506
  4   01516
  5   01535
  6   01650
  7   01737
  8   02206
  9   02311
 10   02312
 11   02370
 12   02456
 13   02457
 14   02460
 15   02461
 16   02510
 17   0615
 18   02512
 19   0730
POS
  1   -872, -1960
  2   -852, -1640
  3   -872, -1128
  4   -852, -832
  5   -872, -544
  6   -852, -252
  7   -872, -88
  8   -852, 168
  9   -872, 236
 10   -852, 508
 11   -872, 500
 12   -852, 748
 13   -872, 724
 14   -852, 932
 15   -872, 936
 16   -852, 1148
 17   -880, -2500
 18   -612, -2540
 99   -1012, -1612
100   -1012, -2292
101   -40, -2450
102   -40, 200
899   -700, 1068
900   609, -3307
990   300, -2400
997   17898, -1629
998   -12207, -719
999   17595, -719
REF
999   POS 999
NOM
  1   8.20000E+00
  2   -4.94600E-01
  3   1.02600E-05
 55   5.00000E+02
397   1.08000E+01
472   8.20000E+00
806   1.04000E+01
837   1.47000E+01
838   1.90000E+00
846   1.45000E+01
861   1.35000E+01
936   1.79000E+01
991   1.26000E+01
1158   9.40000E+00
1225   1.04000E+01
1226   1.05000E+01
1272   1.12000E+01
1326   1.14000E+01
1327   1.04000E+01
1328   1.19000E+01
1329   1.45000E+01
1352   9.35000E+00
SCAN
 55   0, 0, 0, 0
CODE
 55   1, 1, 5, 0
 56   8, 1, 5, 0
TOL
  1   -2.00000E-01, 5.50000E+00
 55   -1.10000E+02, 2.50000E+01
 88   -4.10000E-02, 4.10000E-02
101   -2.00000E-01, 2.00000E-01
151   1.00000E+00, 0.00000E+00
152   0.00000E+00, 1.00000E+00
153   -2.00000E-01, 0.00000E+00
154   0.00000E+00, 5.50000E+00
397   -2.50000E-01, 2.50000E-01
472   -2.00000E-01, 2.00000E-01
806   -2.50000E-01, 2.50000E-01
837   -2.50000E-01, 2.50000E-01
838   -2.50000E-01, 2.50000E-01
846   -2.50000E-01, 2.50000E-01
861   -2.50000E-01, 2.50000E-01
936   -2.50000E-01, 2.50000E-01
991   -2.50000E-01, 2.50000E-01
1158   -2.50000E-01, 2.50000E-01
1225   -2.50000E-01, 2.50000E-01
1226   -2.50000E-01, 2.50000E-01
1272   -2.00000E-01, 2.00000E-01
1326   -2.50000E-01, 2.50000E-01
1327   -2.50000E-01, 2.50000E-01
1328   -2.50000E-01, 2.50000E-01
1329   -2.50000E-01, 2.50000E-01
1352   -2.50000E-01, 2.50000E-01
DUM
  1   1.02600E+01
  2   1.02600E+01
  3   0.00000E+00
  4   0.00000E+00
  5   0.00000E+00
  6   0.00000E+00
  7   0.00000E+00
  8   0.00000E+00
  9   0.00000E+00
 10   0.00000E+00
 55   1.00002E-02
100   2.06000E+00
101   1.20000E+00
102   9.00000E-01
103   7.00000E-01
104   5.00000E-01
105   5.00000E-01
106   4.00000E-01
107   3.00000E-01
108   1.60000E-01
109   1.90000E-01
110   5.50000E+00
201   1.60000E+00
202   1.10000E+00
203   8.00000E-01
204   6.00000E-01
205   5.50000E-01
206   4.50000E-01
207   3.00000E-01
208   1.60000E-01
209   1.90000E-01
210   6.30000E+00
211   1.70000E+00
212   1.30000E+00
213   9.00000E-01
214   6.00000E-01
215   4.00000E-01
216   3.00000E-01
217   2.50000E-01
218   1.60000E-01
219   1.90000E-01
220   6.30000E+00
221   1.60000E+00
222   1.20000E+00
223   8.00000E-01
224   5.00000E-01
225   3.50000E-01
226   2.50000E-01
227   2.00000E-01
228   1.60000E-01
229   1.90000E-01
230   6.00000E+00
231   1.20000E+00
232   9.00000E-01
233   7.00000E-01
234   5.00000E-01
235   5.00000E-01
236   4.00000E-01
237   3.00000E-01
238   1.60000E-01
239   1.90000E-01
240   5.50000E+00
241   1.70000E+00
242   1.30000E+00
243   9.00000E-01
244   6.00000E-01
245   4.00000E-01
246   3.00000E-01
247   2.50000E-01
248   1.60000E-01
249   1.90000E-01
250   6.30000E+00
251   1.60000E+00
252   1.10000E+00
253   8.00000E-01
254   6.00000E-01
255   5.50000E-01
256   4.50000E-01
257   3.00000E-01
258   1.60000E-01
259   1.90000E-01
260   6.30000E+00
333   4.72000E+02
334   4.72000E+02
500   1.78690E+02
501   0.00000E+00
502   0.00000E+00
503   0.00000E+00
504   0.00000E+00
505   0.00000E+00
506   0.00000E+00
507   0.00000E+00
508   0.00000E+00
509   0.00000E+00
600   1.53055E+03
601   0.00000E+00
602   0.00000E+00
603   0.00000E+00
604   0.00000E+00
605   0.00000E+00
606   0.00000E+00
607   0.00000E+00
608   0.00000E+00
609   0.00000E+00
700   2.10000E+01
709   0.00000E+00
800   0.00000E+00
801   1.00000E+00
802   0.00000E+00
803   0.00000E+00
804   0.00000E+00
805   0.00000E+00
806   0.00000E+00
807   2.00000E+00
808   1.00000E+00
809   9.00000E+00
888   4.10000E+01
900   0.00000E+00
901   0.00000E+00
902   0.00000E+00
903   0.00000E+00
904   0.00000E+00
905   0.00000E+00
906   0.00000E+00
907   0.00000E+00
908   0.00000E+00
909   0.00000E+00
998   5.08000E+02
999   4.90000E+01
1000   1.60000E+01
1001   1.98000E+00
1002   2.06000E+00
1003   5.99937E-02
1004   -2.00043E-02
1005   -4.00066E-02
1006   9.99451E-03
1007   -1.00060E-02
1008   8.99963E-02
1009   7.99942E-02
1010   -4.00066E-02
1011   9.99900E+03
1012   9.99900E+03
1013   9.99900E+03
1014   9.99900E+03
1015   9.99900E+03
1016   9.99900E+03
1017   9.99900E+03
1018   9.99900E+03
1019   9.99900E+03
1020   9.99900E+03
1021   9.99900E+03
1022   9.99900E+03
1023   9.99900E+03
1024   9.99900E+03
1025   9.99900E+03
1026   9.99900E+03
1027   9.99900E+03
1028   9.99900E+03
1029   9.99900E+03
1030   9.99900E+03
1031   9.99900E+03
1032   9.99900E+03
1033   9.99900E+03
1034   9.99900E+03
1035   9.99900E+03
1036   9.99900E+03
1037   9.99900E+03
1038   9.99900E+03
1039   9.99900E+03
1040   9.99900E+03
1041   9.99900E+03
1042   9.99900E+03
1043   9.99900E+03
1044   9.99900E+03
1045   9.99900E+03
1046   9.99900E+03
1047   9.99900E+03
1048   9.99900E+03
1049   9.99900E+03
1050   9.99900E+03
1101   9.99900E+03
1102   9.99900E+03
1103   9.99900E+03
1104   9.99900E+03
1105   9.99900E+03
1106   9.99900E+03
1107   9.99900E+03
1108   9.99900E+03
1109   9.99900E+03
1110   9.99900E+03
1111   9.99900E+03
1112   9.99900E+03
1113   9.99900E+03
1114   9.99900E+03
1115   9.99900E+03
1116   9.99900E+03
1117   9.99900E+03
1118   9.99900E+03
1119   9.99900E+03
1120   9.99900E+03
1121   9.99900E+03
1122   9.99900E+03
1123   9.99900E+03
1124   9.99900E+03
1125   9.99900E+03
1126   9.99900E+03
1127   9.99900E+03
1128   9.99900E+03
1129   9.99900E+03
1130   9.99900E+03
1131   9.99900E+03
1132   9.99900E+03
1133   9.99900E+03
1134   9.99900E+03
1135   9.99900E+03
1136   9.99900E+03
1137   9.99900E+03
1138   9.99900E+03
1139   9.99900E+03
1140   9.99900E+03
1141   9.99900E+03
1142   9.99900E+03
1143   9.99900E+03
1144   9.99900E+03
1145   9.99900E+03
1146   9.99900E+03
1147   9.99900E+03
1148   9.99900E+03
1149   9.99900E+03
1150   9.99900E+03
CUT
 55   9.00000E+01
TURN
 55   9.90000E+01
INC
 55   4
SPD
  1   3.30000E+01, 3.30000E+01
  2   3.00000E+00, 3.00000E+00
  3   2.00000E+01, 2.00000E+01
PWR
  1   100, 100
WAIT
  1   1, 2000
STRG
  1   _
  3   
  5   
 10   R20XPCXDFX*XG
 11   O
 12   P+
 13   D
 31   ENTER NEW PART #
 32   ENTER NEW LOT # 
 40   NO DRIFT TEST
300   2472
333   M37B
334   M37B
397   2397
472   2472
501   BAR 1
502   BAR 2
503   BAR 3
504   BAR 4
505   BAR 5
506   BAR 6
507   BAR 7
508   BAR 8
509   BAR 9
806   0806
837   0837
838   0838
846   0846
861   0861
936   0936
991   0991
1000   2472 M18B
1158   1158
1225   1225
1226   1226
1272   1272
1326   1326
1327   1327
1328   1328
1329   1329
1352   1352
DLTA
 99   0, -680
666   620, 0
667   -620, 0
900   1309, -4375
997   -1006, 1267
998   0, 0
999   -620, 0
SCAL
  1   1.15000E+01