G021 REV K SCHEMATIC REV H PCB SENSE AMP TEST for logic (assumes SENSE AMP not driving low) NOTES: disconnect AB2 from tester and attach -15V to UUT. "P" for PULLUP OUTPUTS on the open collector outputs; PINS 1 I AD1 STROBE FIELD 0 2 I AR1 STROBE FIELD 1 3 I AD2 E1-4 INPUT 1 BIT 0 FIELD 0 4 I AE2 E1-3 INPUT 2 BIT 0 FIELD 0 5 I AF2 E2-4 INPUT 1 BIT 0 FIELD 1 6 I AH2 E2-3 INPUT 2 BIT 0 FIELD 1 7 I AL1 E4-4 INPUT 1 BIT 1 FIELD 0 8 I AM1 E4-3 INPUT 2 BIT 1 FIELD 0 9 I AN1 E5-4 INPUT 1 BIT 1 FIELD 1 10 I AP1 E5-3 INPUT 2 BIT 1 FIELD 1 11 I AB1 CLEAR-N 12 I AT2 ENABLE 13 I AC1 BIT 0-N (assume SENSE AMP not driving low) 14 P AA1 OUTPUT 0-N 15 I AS1 BIT 1-N (assume SENSE AMP not driving low) 16 P AU2 OUTPUT 1-N IIIIIIIIIIIIIPIP 0000000000001111 ; remove CLEAR-N 1 ; ENABLE on 1 0 0 ; turn on BIT 0 01 1 ; check ENABLE 0 1 1 1 1 0 ; check CLEAR-N 0 0 1 0 1 1 ; turn on BIT 1 01 1 ; check ENABLE 0 1 1 1 0 1 ; check CLEAR-N 0 0 1 0 1 1 ; turn on BIT 0 and BIT 1 0101 1 1 ; check ENABLE 0 1 1 1 1 1 ; check CLEAR-N 0 0 0 1 0 1 1 END