M360 SCHEMATIC REV B, PCB REV B VARIABLE DELAY LINE USE SINGLE STEP AND DMM. USE OSCILLOSCOPE TO SEE PULSES. TRIGGER ON STEP 5, OBSERVE AS2 POSITIVE PULSE, AT2 NEGATIVE PULSE TRIGGER ON STEP 10, OBSERVE AS2 POSITIVE PULSE, AT2 NEGATIVE PULSE MANUALLY CHANGE DELAY ADJUSTMENT, OBSERVE WITH OSCILLOSCOPE. PINS 1 I AP2 INPUT 1 2 I AR2 INPUT 2 3 O AS2 POSITIVE 100 NS PULSE OUTPUT WHEN (INPUT 1 AND INPUT 2) RISING EDGE 4 P AT2 NEGATIVE OF AS2, NEGATIVE 5 US PULSE OUTPUT (FAST DOWN, RC UP) (OPEN DRAIN) 5 I AU2 INVERTER INPUT 6 P AV2 INVERTER OUTPUT (OPEN DRAIN) IIOPIP ; INITAL OFF 000101 ; NO PULSES 01 00 10 ; PULSE (SO FAST, IT WLL BE OVER BEFORE TESTED) 1101 ;AGAIN WITH INVERTER ON ; INITAL OFF 000110 ; NO PULSES 01 00 10 ; PULSE (SO FAST, IT WLL BE OVER BEFORE TESTED) 1101 ; BACK TO INITAL CONDITIONS 000101 END